CCPF Capacitor Charging Power Supplies

The CCPF family of capacitor charging power supplies utilizes the latest innovations in power electronics to deliver clean and efficient power for pulsed laser applications. A high power resonant inverter insures reliability during all modes of operating conditions. A soft switching power factor circuit ensures near unity power factor with low EMI. CCPF models can drive both PF loads and reservoir charging circuits.
Leakage current is less than 300uA, power factor is greater than 0.99 and conducted emissions meet stringent European regulations. No additional line filter is required to meet EN EN55011 emission requirements.

Available Power Outputs: 500J/sec, 1500J/sec, 2000J/sec, 4000J/sec, 6000J/sec, Output voltage to 20kV

Applications: Lamp Pumped Lasers, Intense Pulsed Light, Excimer Lasers, UV Curing & Sterilization, Medical Laser Systems

Questions & Quotes
Send your request below or call us at 978-241-8260. All fields are required.

Features

  • Ideal Cap Charger for OEM applications.
  • Compact size Capacitor Charger.
  • Low EMI Cap Charger.
  • Available with medical isolation and low leakage.
  • Universal input with active power factor correction, PF > .99.
  • Interface compatible with older LS, LCS, RSC & XLS models.

CCPF Capacitor Chargers Specifications


Shoebox Style Poutmax Voutmax Input Voltage Input Current Size (L x W x H) Wt
CCPF-500-XX 500J/sec 500V to 4kV 90-264VAC 5.5A @115VAC 9.13” x 6” x 3.7” 4.5 lbs
CCPF-1500-XX 1500J/sec 500V to 4kV 90-264VAC 15A @115VAC 12.7” x 5.75” x 4.1” 8 lbs
CCPF-2000-XX 2000J/sec 500V to 4kV 180-264VAC 11A @220VAC 12.7” x 5.75” x 4.1” 8 lbs
CCPF-3500-XX 4000J/sec 500V to 4kV 180-264VAC 20A @220VAC 14.2” x 5.5” x 6” 15 lbs
CCPF-1500-XXSYS* 1500J/sec 500V to 4kV 180-264VAC [email protected] 12.7” x 5.75” x 4.1” 8 lbs
* Includes internal 150mA simmer supply and +24 auxiliary output
Chassis Style Poutmax Voutmax Input Voltage Input Current Size (L x W x H) Wt
CCPF-2000-XX 2000J/sec 500V to 15kV 180-264VAC 11A @220VAC 16.5” x 17.3” x 3.7” 20 lbs
CCPF-6000-XX 6000J/sec 500V to 4kV 180-264VAC 36A @220VAC 16.5” x 17.3” x 3.7” 25 lbs

Input

Voltage: See table above
Current: See table above
Power Factor: >.98

Output

Power: See table above
Output Voltage: Configurable from 500V to 15kV.
Output Current: 2 * Poutmax/Voutmax
Polarity: Positive or Negative
Efficiency: >80% at full outp

Interface

Connector: 15 Pin “D” Sub Female
Voltage Program: 0-10V for 0-Max Voltage
Voltage Monitor: 0-10V for 0-Max Voltage

  • Inhibit/Reset
  • End of Charge Indication
  • Temperature Fault
  • Over-voltage Indication

Environment

Operating Temp: 0 to 40°C
Storage: -20 to 85°C
Humidity: 0 to 90% non-condensing
Cooling: Forced air

Regulatory

Leakage Current: <300uA
Isolation: 4000VAC/5700VDC
EMI: EN55011
(depending upon Model)

CCPF Capacitor Chargers CCPF Series Pin Assignment


Pin# 500/4pin 500/15pin 1500/2000 3500 6000
1 Inhibit Inhibit Inhibit Inhibit Inhibit
2 GND N/C N/C NV On N/C
3 V Program N/C Overtemp Overtemp Overtemp
4 N/C GND N/C N/C N/C
5 N/C V Program V Program V Program V Program
6 N/C N/C Overvoltage Overvoltage Overvoltage
7 N/C V Peak Hold V Peak Hold V Peak Hold V Peak Hold
8 N/C V Monitor V Monitor V Monitor V Monitor
9 N/C +15V +15V +15V +15V
10 N/C N/C N/C N/C N/C
11 N/C N/C +15V +15V +15V
12 N/C N/C N/C N/C +15V
13 N/C End of Charge End of Charge End of Charge End of Charge
14,15 N/C GND GND GND GND
In most cases interface configurations can be modified to conform to older capacitor charger models. Contact customer service if you are trying to replace RCS, CCS, LCS, LS, 5XX, 1XX, 57XX, 78XX or other models up to 8kj/sec. Note: Non connected (N/C) pins should not be used or grounded.

TITLE/DESCRIPTION

  • INHIBIT/FAULT RESET- (INPUT)
    This pin is the basic ON/OFF control pin for the power supply.
    Grounding this pin enables charging operation if all faults are
    clear. Applying +15V prevents the inverter from operating. Leaving
    Pin open will inhibit operation.(opposite option available)

    FAULT WARNING – (OUTPUT)
    When either the over-voltage fault pin, or the OVER-TEMP FAULT
    indicates a fault status, pin is pulled to GND through the collector
    of an NPN transistor. This transistor is rated at 30V, 100mA.
    When no fault is present, the output of this pin is connected to
    +15V through a 4.99K resistor. This fault can be cleared by applying
    +15V to INHIBIT/FAULT RESET function.

    OVER-TEMP FAULT – (OUTPUT)
    Indicates internal high temperature on main heat sink. When
    thermal switch closes due to excessive internal heat sink temperature
    this pin is pulled to GND through the collector of an NPN
    transistor. This transistor is rated at 30V, 100mA. When OVERTEMP
    WARNING is tripped, unit will stop charging and will not
    begin charging again until the internal temperature drops to a
    safe value. When the unit is operating within safe temperatures,
    the output of this pin is connected to +15V through a 4.99K resistor.
    This fault can be cleared by applying +15V to INHIBIT/FAULT
    RESET function.

    VOLTAGE PROGRAM- (INPUT)
    Output is programmed externally with a 0 to +10V signal for 0 to
    100% of rated output.

  • OVERVOLTAGE STATUS INDICATOR- (OUTPUT)
    If the load becomes open circuited, the power supply will detect
    the fault and shut down instantaneously, protecting itself and other
    equipment from over-voltages. If this occurs the pin is pulled to
    GND through the collector of an NPN transistor. This transistor
    is rated at 30V, 100mA. To restart, a capacitor load must be connected to the output and AC power must be turned OFF and ON
    again. When an appropriate load is connected to the output, the
    output of this pin is connected to +15V through a 4.99K resistor.
    This fault can be cleared by applying +15V to INHIBIT/FAULT
    RESET function.

    VOUT PEAK HOLD- (OUTPUT)
    Monitors output voltage with a peak hold circuit. The time constant
    of the peak hold circuit is approximately 5 seconds. 0 to
    +10V for 0 to 100% of rated output voltage.

    VOUT MONITOR- (OUTPUT)
    Monitors output voltage. 0 to +10V for 0 to 100% of rated output
    voltage.

    +15V (OUTPUT)
    Maximum output current is 100mA.

    END OF CHARGE STATUS INDICATOR-(OUTPUT)
    When the load capacitor reaches the programmed voltage this
    pin is pulled to GND through the collector of an NPN transistor.
    This transistor is rated at 30V, 100mA. While the load capacitor
    is being charged to the programmed voltage, the output of this
    pin is +15V through a 10kΩ resistor. Pin will oscillate from high to
    low as the power supply

CCPF Capacitor Charging Power Supplies Outline Drawings